[Lead2pass New] Lead2pass Offering New 300-175 Exam PDF And 300-175 Exam VCE Dumps For Free Downloading (61-80)
Lead2pass 2017 August New Cisco 300-175 Exam Dumps! 100% Free Download! 100% Pass Guaranteed! Our PDF dumps of 300-175 exam is designed to ensure everything which you need to pass your exam successfully. At Lead2pass, we have a completely customer oriented policy. We invite the professionals who have rich experience and expert knowledge of the IT certification industry to guarantee the PDF details precisely and logically. Our customers' time is a precious concern for us. This requires us to provide you the products that can be utilized most efficiently. Following questions and answers are all new published by Cisco Official Exam Center: https://www.lead2pass.com/300-175.html QUESTION 61 Which two elements are defined in a dynamic vNIC connection policy? (Choose two.) A. adapter policy B. QoS policy C. network control policy D. number of dynamic vNICs E. jumbo frame size Answer: AD QUESTION 62 Which two of the listed BIOS options are required for VM-FEX in high performance mode? (Choose two.) A. RSS B. interrupt coherency C. virtualization technology D. cache validation E. ATS support Answer: CE QUESTION 63 Which item represents a secure method of transmitting fault data with Cisco Call Home? A. IPsec B. SSL email C. secure XML D. Cisco Transport Gateway E. RSA Digital Certificate Answer: D QUESTION 64 Which item is required for communication between Cisco Unified Computing System Manager and VMware vCenter? A. VeriSign Digital Certificates B. RSA Digital Certificates C. Cisco Unified Computing System Manager Extension Key D. VeriSign Plug-In E. WMware vCenter Certificate Services Answer: C QUESTION 65 How many certificates does Cisco Unified Computing System Manager have to export to communicate with VMware vCenter server if the VMware ESXi hosts are all running version 5.0 or higher? A. 1 B. 2 C. 4 D. 8 E. 16 Answer: A QUESTION 66 What is the purpose of the maximum ports that are filed in the port profile? A. determines the maximum number of uplinks that VMs can use B. determines the maximum number of VMs that can use the DVS C. determines the maximum number of DVSs that can use the port profile D. determines the maximum number of dynamic vNICS on the DVS Answer: D QUESTION 67 What is the maximum number of ports on a VMware vCenter Distributed Virtual Switch? A. 64 B. 128 C. 1024 D. 4096 E. 8192 Answer: D QUESTION 68 In the Create Dynamic vNIC Connection Policy dialog box, there is a configurable field titled Protection. What is the significance of the three choices for Protection? A. allows reserve vNICs to be allocated out of the spares pool B. enables hardware-based failover C. enables static binding of the VM port profile to dynamic vNICs D. selects the primary fabric association for dynamic vNICs E. allows dynamic vNICs to be reserved for fabric failover Answer: D QUESTION 69 How does a dynamic vNIC get allocated? A. Dynamic vNICs are assigned to VMs in VMware vCenter. B. Dynamic vNICs can only be bound to the service profile through an updating template. C. Dynamic vNICs are bound directly to a service profile. D. Dynamic vNICs are assigned by binding a port profile to the service profile. Answer: C QUESTION 70 After staging a VEM file on a VMware ESXi 5.0 host in the /tmp directory, what is the correct command syntax to install the VEM? A. esxcli software vib install -d /tmp/VEM500-20110825132140-BG-release.zip -maintenance-mode B. esxcli software vib install -v /tmp/VEM500-20110825132140-BG-release.zip -maintenance-mode C. esxupdate software vib install -d /tmp/VEM500-20110825132140-BG-release.zip -maintenance-mode D. esxupdate software vib install -v /tmp/VEM500-20110825132140-BG-release.vib -maintenance-mode Answer: A QUESTION 71 Which network driver is required on a VMware ESXi 5.0 host for a vNIC to enter Cisco VM-FEX universal passthrough mode? A. VMXNET3 B. Vlance C. Flexible D. E1000e E. VMXNET5 Answer: A QUESTION 72 Which virtual hardware version is required for a VM to enter the Cisco VM-FEX universal passthrough mode? A. Version 5 B. Version 6 C. Version 7 D. Version 8 E. Version 9 Answer: D QUESTION 73 Which feature must be configured for Linux VMs to be able to transition from Cisco VM-FEX standard mode to universal passthrough mode? A. RSS B. MSI Interrupt Mode C. VEMDPA Agent D. Execute Disabled Bit E. Processor C State Answer: B QUESTION 74 Which of the following is true concerning the Global Chassis Discovery policy configuration on the Cisco Unified Computing System Manager when using Cisco Unified Computing System 22XX I/O modules with Cisco UCS 62XX Fabric Interconnects? A. The link grouping preference should be set to discrete mode when the number of northbound links are not a power of 2. B. Set the action policy-count higher than the actual number of uplinks; otherwise, the Cisco Unified Computing System servers will not be discovered. C. For Cisco Unified Computing System implementations that mix I/O modules with different numbers of links, it is best to manually reacknowledge the chassis in order to use all available links. D. Automatic reacknowledgement due to chassis discovery is never disruptive. Answer: C QUESTION 75 Which of the following is the most accurate concerning the link configuration between Cisco Unified Computing System 22XX I/O modules and Cisco Unified Computing System 62XX Fabric Interconnects? A. Port channels are always recommended when using source-dest-mac load balancing. B. The addition of links to a port channel requires a reacknowledgement. C. You cannot mix and match discrete links and port channeling for different chassis when using 22XX. D. Port channels do not require a Global Chassis Discovery policy. Answer: A QUESTION 76 Which of the following is not a feature of the Cisco Unified Computing System VIC-1280 adaptor? A. capable of up to 256 virtual interfaces B. supports FCoE C. supports Cisco VM-FEX D. compatible with the C- or B-Series Cisco Unified Computing System servers Answer: D QUESTION 77 Which of the following is true with respect to recovery from failure with automatic pinning that is configured on a cluster of Cisco Unified Computing System 62XX Fabric Interconnects? A. By default, server MAC addresses are pinned to uplink interfaces using PIN groups. B. When a northbound fabric interconnect link goes down, the affected servers will use NIC teaming to re-establish connectivity on the second fabric interconnect. C. When a northbound fabric interconnect link goes down, the fabric interconnect will send a gratuitous ARP to the northbound switch to announce the servers on the new port. D. In the event that all uplink ports on the fabric interconnect lose connectivity, the 22XX I/O module shuts down all of the host ports until at least one uplink is restored. Answer: C QUESTION 78 How does a Cisco Unified Computing System react when configured for disjoint Layer 2 domains? A. Automatic pinning is disabled; VLAN membership must be statically pinned to the uplink ports. B. VLANs must be divided between the fabric interconnects using PIN groups. C. The VLAN traffic for a disjoint network can only travel along an uplink that is specifically assigned to this VLAN and is selectively excluded from all other uplinks. D. When you configure disjoint Layer 2 networks, you must assign VLANs to uplink interfaces. Answer: C QUESTION 79 Which of the following is true with respect to hardware failover or NIC teaming within a Cisco Unified Computing System? A. Hardware failover is specified by the operating system. B. An uplink failure when using automatic pinning requires that hardware failover for the server vNIC be disabled. C. NIC teaming is controlled by the vNIC. D. The hardware failover option that is available for Ethernet does not affect Fibre Channel traffic. Answer: D Hotspot Question (QUESTION 80 - QUESTION 86) QUESTION 80 Answer: More free Lead2pass 300-175 exam new questions on Google Drive: https://drive.google.com/open?id=0B3Syig5i8gpDVDYyRldqb1AzenM If you want to get more 300-175 exam preparation material, you can download the free 300-175 braindumps in PDF files on Lead2pass. It would be great helpful for your exam. All the 300-175 dumps are updated and cover every aspect of the examination. Welcome to choose. 2017 Cisco 300-175 (All 255 Q&As) exam dumps (PDF&VCE) from Lead2pass: https://www.lead2pass.com/300-175.html [100% Exam Pass Guaranteed]
|